Method and research
How Positus measures movement.
Markerless motion capture from two phones, grounded in published biomechanics research.
From two videos
to measurements.
Positus uses markerless motion capture. Nothing is attached to the body; the measurements come from ordinary video.
- 01
Two views
Two phones record the same movement at the same time, from different angles.
- 02
Body landmarks
Software locates body landmarks, such as the joints, in every frame of each video.
- 03
Movement in three dimensions
The two views are combined into a three-dimensional estimate of the movement, from which joint angles and body positions are calculated.
Every point becomes a measurement.
Joint kinematics through every repetition, walking, running or exercising, and how movement changes as fatigue builds.
The movement study on the home page shows the kind of measurements this produces, using an illustrative figure.
The research behind
markerless capture.
Markerless motion capture measures how the body moves from ordinary video: joint angles, body position and the timing of each step, with nothing attached to the body.
Published studies comparing it with marker-based laboratory systems report joint angles within a few degrees during walking and everyday movements, and consistent results from one session to the next. A selection:
OpenCap: Human movement dynamics from smartphone videos
PLOS Computational Biology
Two smartphones measured joint angles during walking, squats, sit-to-stand and jumping in 10 adults, with a mean absolute error of 4.5 degrees against marker-based motion capture.
- People
- 10 adults
- Movements
- Walking, squats, sit-to-stand, jumping
- Setup
- Two smartphones against marker-based motion capture
Concurrent assessment of gait kinematics using marker-based and markerless motion capture
Journal of Biomechanics
In 30 adults walking on a treadmill, markerless and marker-based estimates of hip, knee and ankle joint centres agreed within 2.2 to 3.6 centimeters.
- People
- 30 adults
- Movements
- Treadmill walking
- Setup
- A video-based markerless system against marker-based motion capture, recorded together
Inter-session repeatability of markerless motion capture gait kinematics
Journal of Biomechanics
In 8 adults recorded in three sessions about a week apart, variability between sessions (2.8 degrees) was close to variability between walking trials within one session (2.5 degrees).
- People
- 8 adults
- Movements
- Walking
- Setup
- Three sessions about a week apart
Markerless motion capture estimates of lower extremity kinematics and kinetics are comparable to marker-based across 8 movements
Journal of Biomechanics
Across eight movements in 10 adults, knee and ankle angles differed from marker-based capture by less than 5.9 degrees.
- People
- 10 adults
- Movements
- Eight movements
- Setup
- Markerless against marker-based capture, joint angles and forces
Each study describes the system, people and movements it tested.
See Positus in a
clinical workflow.
Walk through the capture process, explore the measurements, and discuss how Positus could fit into your practice.
Request a demo- Two ordinary phones and a clear capture area.
- Opens your email app. Business inquiries only.
- Please do not include patient information.

